SM Polymers

Nashik, Maharashtra

GST 27AGHPP6698L1ZE

TrustSeal Verified

Gas Chlorinators

SM-207 Floor Mounting Chlorinator

Ask Price

SM-207 Floor Mounting Chlorinator
  • Model/Type: SM-207
  • Material: MS
  • Applications: Water Filtration Plants, Cooling Water Systems
  • Cabinet: Self Colored Fiber Glass
  • Meter Ratio: 20 1
  • Model/Type: SM-207
  • Material: MS
  • Applications: Water Filtration Plants, Cooling Water Systems
  • Cabinet: Self Colored Fiber Glass
  • Filter: Stainless steel body with inside PTFE Silver Metal coating & fine glass wool
  • Meter Ratio: 20 1
  • Maximum Working Pressure: 15kg / cm2
Description The SM 207 Model SMPM Chlorinator is designed for Continuous & constant flow of Chlorine/Sulphurdioxide or Ammonia Gas in fully vacuum mode, also designed with differential vacuum controller chamber, flow meter, gas flow control valve, Chlorine / Water pressure gauges, vacuum gauges and gas filter, also an injector to connect motive water and point of application.
Flow Meter Ranges
  • SM-207A 1000gms./ hr. to 10,000 gms. / hr.
  • SM-207B 2000gms./ hr. to 20,000 gms. / hr.
  • SM-207C 3000gms./ hr. to 30,000 gms. / hr.

Principle of Operation In SM-207 Model SMPM Chlornator is operated under vacuum. The vacuum created in the injector by water pressure is passed through PVC piping / tubing to the Differential vacuum regulator Chamber via control valve.
Gas from Cylinder/Tonner passes through PVC coated copper tubing & enters a gas filter assembly where moisture and foreign particles are removed and send to differential vacuum regulator. Here, the diaphragm assembly dislocates inlet valve with the help of vacuum on one side, atmosphere pressure on the other and allows the gas to flow through flow meter via control valve where the flow rate of gas can be adjusted manually
The gas passes to the injector where it is mixed with water in the mixing chamber and the solutions is discharged to the point of applications. If the water supply to the injector fails or any block in vacuum the inlet valve inside vacuum regulator assembly immediately isolates the gas under pressure and stops the flow of gas even though the cylinder valve is open and the gas inside the system is exhausted through the vent via relief valve.
know more

Cylinder Mounted Chlorinator - SM-117

Ask Price

Cylinder Mounted Chlorinator - SM-117
  • Construction material: Non corrosive materials like monel, PVC, Borosilicate Glass, UHMWHDPE, PTFE (Teflon), Hastelloy "C"
  • Meter Ratio: 20 1
  • Deals in: new
  • Construction material: Non corrosive materials like monel, PVC, Borosilicate Glass, UHMWHDPE, PTFE (Teflon), Hastelloy "C"
  • Meter Ratio: 20 1
  • Water Pipe Connection Tail: 25 / 32 inch Dia
  • Vacuum Tubing: 9 mm ID soft polyethylene tube
  • Maximum working back pressure: 7 kg / cm2
  • Deals in: new
The Cylinder mounted vacuum type gas chlorinator SM-117 is designed for assuring safety & Space saving Gas Chlorinator, consist of vacuum regulator, rotameter, flow control valve, Yoke clamp to connect directly on cylinder A gas filter, a injector assembly vent & vacuum tubing of 5 meters.
Principle of Operation Water Under pressure passes through injector cause vacuum, which open spring loaded diaphragm check valve. Vacuum passes through vacuum tubing to the chlorinator.

When cylinder/Tonner valve open chlorine passes through self aligned yoke gas filter where foreign particles are removed if present, chlorine gas passes to regulator where the cylinder pressure is controlled by the inlet valve assembly When vacuums adjusted by control valve vacuum opened the inlet valve with the help of diaphragm assembly and allowed chlorine gas to passes through flow meter where flow can be adjusted an to injector & point of application.

If any break in the vacuum line occur the system automatically shut off the chlorine gas supply.
Material Of Construction Totally non corrosive materials are used in chlorinator such as UHMWHDPE, PTFE (Teflon), monal, PVC, Borosilicate Glass, Hastelloy "C", PVDF, VITON etc
know more

Stand Base Mounting Chlorinator

Ask Price

Stand Base Mounting Chlorinator
  • Installation Service: Yes
  • Brand/make: SM POLYMERS
  • Capacity: 20 KG/HR
  • Usage: WATER TREATMENT PLANT/SWIMMING POOL
  • Model/Type: SM-108
  • Color: WHITE
  • Minimum Order Quantity: 1 Piece
  • Installation Service: Yes
  • Brand/make: SM POLYMERS
  • Capacity: 20 KG/HR
  • Usage: WATER TREATMENT PLANT/SWIMMING POOL
  • Model/Type: SM-108
  • Color: WHITE
  • Warranty: 1 YEAR
Description The SM 108 Model SBM Chlorinator is designed for Continuous & constant flow of Chlorine / Sulphur dioxide or Ammonia Gas in fully vacuum mode, designed with vacuum controller chamber, flow meter, gas flow control valve, Chlorine / Water pressure gauges, a gas filter, a injector to connect motive water, and point of application
Principle of Operation In SM-108 Model the Chlorinator is operated under vacuum .The vacuum created in the injector by water pressure passes through PVC piping / tubing to the vacuum regulator chamber via control valve
Gas from Cylinder / Tonner passes through PVC coated copper tubing & enters a gas filter assembly where moisture and foreign particles are removed and send to differential vacuum regulator. Here, the diaphragm assembly dislocates inlet valve with the help of vacuum on one side, atmosphere pressure on the other and allows the gas to flow through flow meter via control valve where the flow rate of gas can be adjusted manually
The gas passes to the injector where it is mixed with water in the mixing chamber and the solutions is discharged to the point of applications. If the water supply to the injector fails or any block in vacuum the inlet valve inside vacuum regulator assembly immediately isolates the gas under pressure and stops the flow of gas even though the cylinder valve is open and the gas inside the system is exhausted through the vent via relief valve.
Areas of Application
  • Water Filtration Plants
  • Sewage Treatment Plants
  • Cooling Water Systems
  • Industrial Effuent Treatment
know more

Explore More Categories

x

Send us a Quick Message

country flag
x

Provide Us More Details

Purpose of Requirement:

Reselling End Use Raw Material

We recommend you to enter details of your requirement to get quick quotations.
Back

SM Polymers